Support / Re: Curve loses its temp probe between roasts
« on: November 14, 2017, 09:44:02 AM »
Seems like many users want the ET/BT probes connected after COPYING a previous roast.
Danny gave a wonderful answer here --- Solved the problem :-)
https://rainfroginc.com/frogpad/index.php?topic=223.0
Danny gave a wonderful answer here --- Solved the problem :-)
https://rainfroginc.com/frogpad/index.php?topic=223.0
Sounds like you're missing the binding field in the corresponding curve template of the profile you're using. Have a look at the profile the roast is using to make sure all curve templates have their binding set.
For a number of reasons, the copy function for roasts gives precedence to a profile-based workflow - it does not actually look at the data curves of the source roast. So, when you copy a roast, the copy grabs the profile from the source roast, and populates its Data Curves from the templates it finds there. One of those is probably missing its binding - or, it has outdated binding information.